V Congreso Latinoamericano de Ingeniería Biomédica (CLAIB2011)

Potencial Evocado Auditivo de Latencia Media con Pip´s en sujetos sanos.
Quintana López Agar Karina, Granados Trejo María del Pilar, Cornejo Cruz Juan Manuel

##manager.scheduler.building##: Palacio de Convenciones de La Habana
##manager.scheduler.room##: Sala 8
Fecha: 2011-05-20 01:30  – 01:45
Última modificación: 2011-04-15 06:14

Resumen


This work deals with the amplitude and latency characterization of the Middle Latency Auditory Evoked Potential (MLAEP) Pa peak in normal subjects. Stimuli were tone pips of 0.5, 1, 2 and 3 kHz for an intensity range of 0 to 40 dBHL. Results show Pa amplitude behavior does not follow a know model, on the other hand, changes in Pa latency due to changes in intensity and frequency of the stimulus can be described by a second order polynomial;  Pa latency decreases as stimulus intensity and frequency decreases.  Methodology used for improving signal to noise ratio for Pa detection may be a tool that contribute to achieve a better Objective Audiometry estimation.